GEORG FISCHER
pH and ORP electrodes are general purpose sensors ideal for a wide range of applications. These feature a patented reference design and uses the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway is constructed to increase the total reference eff ectiveness and ensures long service life.
The DryLoc® connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifi er. The robust PPS threaded sensor body and choice of fl at pH, bulb pH, or fl at ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications.
There are two optional pH sensing versions available, HF and LC. The HF version is for applications where traces of hydrofl uoric acid (2% or less) will attack standard pH glass. The LC version can be used for low conductivity fl uids 20 - 100 µS/cm nominal and below 20 µS/cm when mounted under controlled conditions.
The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all pH/ORP instruments. The 2724- 2726 electrodes incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into GF standard pipe-tees. They can also be mounted directly into standard fi ttings, DN15 to DN100 (½ to 4 inch)
pH and ORP electrodes are general purpose sensors ideal for a wide range of applications. These feature a patented reference design and uses the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway is constructed to increase the total reference eff ectiveness and ensures long service life.
The DryLoc® connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifi er. The robust PPS threaded sensor body and choice of fl at pH, bulb pH, or fl at ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications.
There are two optional pH sensing versions available, HF and LC. The HF version is for applications where traces of hydrofl uoric acid (2% or less) will attack standard pH glass. The LC version can be used for low conductivity fl uids 20 - 100 µS/cm nominal and below 20 µS/cm when mounted under controlled conditions.
The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all pH/ORP instruments. The 2724- 2726 electrodes incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into GF standard pipe-tees. They can also be mounted directly into standard fi ttings, DN15 to DN100 (½ to 4 inch)
We’re excited to share some great news at Demesne Electrical. Wayne Moody has joined our team, bringing with him years of experience and a clear vision for the future. His focus will be on building on our strong reputation here in Ireland and driving our growth across Europe.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
STEGO’s new loop enclosure heaters are a smart fix for condensation in control cabinets. They heat evenly, install fast with no tools, and come in a range of sizes from 10 to 150 W. They're tough, touch-safe, and even have a built-in thermostat option—everything you need to protect your gear and keep things running smoothly.
Precise, Durable Linear Measurement from Kübler
Browse our range of Kübler draw wire encoders and linear measurement systems, designed for accurate position and speed sensing in industrial and OEM applications. Built for tough environments. Trusted by automation professionals.
Designed by HORA eTec, the RKA series offers a complete lineup of aluminium terminal blocks built for both aluminium and copper conductors. Every model in the range includes push-through protection, is finger-safe, and is built with installation efficiency in mind. From compact control panels to large-scale systems, here’s the full breakdown—from the RKA 16 to the RKA 300.
In complex, high-stakes electrical environments, precision, safety, and performance aren't optional, they're essential. That’s why at Demesne Electrical, we supply solutions that go beyond compliance, empowering engineers and panel builders to build smarter, more connected systems.
One of our most trusted partners in this space is TELE Haase, an industry leader in intelligent monitoring and automation components. From load protection to digital performance sensors, the TELE range offers future-focused tools that streamline system diagnostics and improve long-term reliability.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
My favourites | Articles | Price | |
---|---|---|---|
![]()
2724 - pH electrode, PT1000, flat tip, 3/4in NPT thread, use with 2751
Art:
159001545
Copied
|
| ||
![]()
2724 - pH electrode, PT1000, flat tip, 3/4in ISO thread, use with 2751
Art:
159001546
Copied
|
| ||
![]()
2725 - ORP electrode, flat tip, 3/4in NPT thread, use with 2751
Art:
159001561
Copied
|
| ||
![]()
2725 - ORP electrode, flat tip, 3/4in ISO thread, use with 2751
Art:
159001562
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, use with 2751
Art:
159001553
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, use with 2751
Art:
159001554
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, HF resistant, use with 2751
Art:
159001549
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, HF resistant, use with 2751
Art:
159001550
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, low conductivity, use with 2751
Art:
159001557
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, low conductivity, use with 2751
Art:
159001558
Copied
|
|
Select a variant in the list