ESI
The PR3860 high temperature pressure transmitter has been designed to meet the requirements of the majority of industrial pressure measurement applications where a hygienic flush diaphragm connection is required.Suitable for use at media temperature up to
250°C. Typical applications include food processing, pharmaceutical and petrochemical. The flush membrane can be easily cleaned for long term reliability and outstanding performance. The PR3860 offers a stable and accurate output signal of 4-20 mA with options for 0-5 Vdc, 0-10 Vdc, 0-20 mA and other output signals. Electrical connection is via a detachable DIN connector allowing easy access to zero and span adjustment. Pressure ranges available from 0-10 bar to 0-400 bar.
Optional weldable boss is available to ensure flush-face installation of transmitter to tanks and pipe-work.
An optional ATEX and IECEx approved version of this product is available for explosion protection for flammable gases (zone 0), dusts (zone 20) and mining areas (group I M1).
| Ambient temperature | -20..85°C |
|---|---|
| Approvals | CE, IEC |
| Electrical connection | DIN A 43650 |
| EMC | EN61000-6-2, EN61000-6-4 |
| Linearity | ≤±0.3% BSFL |
| Materials Wetted Parts | Stainless steel 316L |
| Media temperature | 0..205°C |
| Output | 4-20 mA |
| Overpressure protection | 15 bar |
| Pressure Range Max | 10 |
|---|---|
| Pressure Range Min | 0 |
| Pressure reference | Gauge |
| Process connection | G1/2" flush diaphragm |
| Sensor technology | Ceramic thick film |
| Storage temperature | 5..40°C |
| Supply voltage | 13-36 V DC |
The PR3860 high temperature pressure transmitter has been designed to meet the requirements of the majority of industrial pressure measurement applications where a hygienic flush diaphragm connection is required.Suitable for use at media temperature up to
250°C. Typical applications include food processing, pharmaceutical and petrochemical. The flush membrane can be easily cleaned for long term reliability and outstanding performance. The PR3860 offers a stable and accurate output signal of 4-20 mA with options for 0-5 Vdc, 0-10 Vdc, 0-20 mA and other output signals. Electrical connection is via a detachable DIN connector allowing easy access to zero and span adjustment. Pressure ranges available from 0-10 bar to 0-400 bar.
Optional weldable boss is available to ensure flush-face installation of transmitter to tanks and pipe-work.
An optional ATEX and IECEx approved version of this product is available for explosion protection for flammable gases (zone 0), dusts (zone 20) and mining areas (group I M1).
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
We’re excited to share some great news at Demesne Electrical. Wayne Moody has joined our team, bringing with him years of experience and a clear vision for the future. His focus will be on building on our strong reputation here in Ireland and driving our growth across Europe.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
STEGO’s new loop enclosure heaters are a smart fix for condensation in control cabinets. They heat evenly, install fast with no tools, and come in a range of sizes from 10 to 150 W. They're tough, touch-safe, and even have a built-in thermostat option—everything you need to protect your gear and keep things running smoothly.
Precise, Durable Linear Measurement from Kübler
Browse our range of Kübler draw wire encoders and linear measurement systems, designed for accurate position and speed sensing in industrial and OEM applications. Built for tough environments. Trusted by automation professionals.
Designed by HORA eTec, the RKA series offers a complete lineup of aluminium terminal blocks built for both aluminium and copper conductors. Every model in the range includes push-through protection, is finger-safe, and is built with installation efficiency in mind. From compact control panels to large-scale systems, here’s the full breakdown—from the RKA 16 to the RKA 300.
|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| My favourites | Articles | Atex Approvals | Atex approved | Electrical connection | Output | Overpressure protection | Pressure Range Max | Supply voltage | Price | |
|---|---|---|---|---|---|---|---|---|---|---|
|
4-20mA, 0..10 bar, G1/2 flush, DIN
Art:
PR3860-0010BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
15 bar
|
10
|
13-36 V DC
|
| ||
|
4-20mA, 0..25 bar, G1/2 flush, DIN
Art:
PR3860-0025BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
37.5 bar
|
25
|
13-36 V DC
|
| ||
|
4-20mA, 0..60 bar, G1/2 flush, DIN
Art:
PR3860-0060BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
90 bar
|
60
|
13-36 V DC
|
| ||
|
4-20mA, 0..100 bar, G1/2 flush, DIN
Art:
PR3860-0100BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
150 bar
|
100
|
13-36 V DC
|
| ||
|
4-20mA, 0..250 bar, G1/2 flush, DIN
Art:
PR3860-0250BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
375 bar
|
250
|
13-36 V DC
|
| ||
|
4-20mA, 0..400 bar, G1/2 flush, DIN
Art:
PR3860-0400BA
Copied
|
|
|
DIN A 43650
|
4-20 mA
|
600 bar
|
400
|
13-36 V DC
|
| ||
|
4-20mA, 0..10 bar, G1/2 flush, 1M cable
Art:
PR3860A0010BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
15 bar
|
10
|
13-36 V DC
|
| ||
|
4-20mA, 0..25 bar, G1/2 flush, 1M cable
Art:
PR3860A0025BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
37.5 bar
|
25
|
13-36 V DC
|
| ||
|
4-20mA, 0..60 bar, G1/2 flush, 1M cable
Art:
PR3860A0060BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
90 bar
|
60
|
13-36 V DC
|
| ||
|
4-20mA, 0..100 bar, G1/2 flush, 1M cable
Art:
PR3860A0100BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
150 bar
|
100
|
13-36 V DC
|
| ||
|
4-20mA, 0..250 bar, G1/2 flush, 1M cable
Art:
PR3860A0250BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
375 bar
|
250
|
13-36 V DC
|
| ||
|
4-20mA, 0..400 bar, G1/2 flush, 1M cable
Art:
PR3860A0400BA
Copied
|
|
|
1M Cable outlet screened
|
4-20 mA
|
600 bar
|
400
|
13-36 V DC
|
| ||
|
4-20mA, 0..10 bar, G1/2 flush, M12
Art:
PR3860B0010BA
Copied
|
|
|
M12
|
4-20 mA
|
15 bar
|
10
|
13-36 V DC
|
| ||
|
4-20mA, 0..25 bar, G1/2 flush, M12
Art:
PR3860B0025BA
Copied
|
|
|
M12
|
4-20 mA
|
37.5 bar
|
25
|
13-36 V DC
|
| ||
|
4-20mA, 0..60 bar, G1/2 flush, M12
Art:
PR3860B0060BA
Copied
|
|
|
M12
|
4-20 mA
|
90 bar
|
60
|
13-36 V DC
|
| ||
|
4-20mA, 0..100 bar, G1/2 flush, M12
Art:
PR3860B0100BA
Copied
|
|
|
M12
|
4-20 mA
|
150 bar
|
100
|
13-36 V DC
|
| ||
|
4-20mA, 0..250 bar, G1/2 flush, M12
Art:
PR3860B0250BA
Copied
|
|
|
M12
|
4-20 mA
|
375 bar
|
250
|
13-36 V DC
|
| ||
|
4-20mA, 0..400 bar, G1/2 flush, M12
Art:
PR3860B0400BA
Copied
|
|
|
M12
|
4-20 mA
|
600 bar
|
400
|
13-36 V DC
|
| ||
|
4-20mA, 0..10 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0010BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
15 bar
|
10
|
13-36 V DC
|
| ||
|
4-20mA, 0..25 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0025BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
37.5 bar
|
25
|
13-36 V DC
|
| ||
|
4-20mA, 0..60 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0060BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
90 bar
|
60
|
13-36 V DC
|
| ||
|
4-20mA, 0..100 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0100BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
150 bar
|
100
|
13-36 V DC
|
| ||
|
4-20mA, 0..250 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0250BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
375 bar
|
250
|
13-36 V DC
|
| ||
|
4-20mA, 0..400 bar, G1/2 flush, 1M cable IP67
Art:
PR3860C0400BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
4-20 mA
|
600 bar
|
400
|
13-36 V DC
|
| ||
|
4-20mA, 0..10 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0010BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
15 bar
|
10
|
13-36 V DC
|
| ||
|
4-20mA, 0..25 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0025BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
37.5 bar
|
25
|
13-36 V DC
|
| ||
|
4-20mA, 0..60 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0060BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
90 bar
|
60
|
13-36 V DC
|
| ||
|
4-20mA, 0..100 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0100BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
150 bar
|
100
|
13-36 V DC
|
| ||
|
4-20mA, 0..250 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0250BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
375 bar
|
250
|
13-36 V DC
|
| ||
|
4-20mA, 0..400 bar, G1/2 flush, DIN, Ex
Art:
PR3860EX0400BA
Copied
|
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
|
Yes
|
DIN A 43650
|
4-20 mA
|
600 bar
|
400
|
13-36 V DC
|
| ||
|
0-5V, 0..10 bar, G1/2 flush, DIN
Art:
PR3861-0010BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-5V, 0..25 bar, G1/2 flush, DIN
Art:
PR3861-0025BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-5V, 0..60 bar, G1/2 flush, DIN
Art:
PR3861-0060BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-5V, 0..100 bar, G1/2 flush, DIN
Art:
PR3861-0100BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-5V, 0..250 bar, G1/2 flush, DIN
Art:
PR3861-0250BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-5V, 0..400 bar, G1/2 flush, DIN
Art:
PR3861-0400BA
Copied
|
|
|
DIN A 43650
|
0-5V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-5V, 0..10 bar, G1/2 flush, 1M cable
Art:
PR3861A0010BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-5V, 0..25 bar, G1/2 flush, 1M cable
Art:
PR3861A0025BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-5V, 0..60 bar, G1/2 flush, 1M cable
Art:
PR3861A0060BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-5V, 0..100 bar, G1/2 flush, 1M cable
Art:
PR3861A0100BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-5V, 0..250 bar, G1/2 flush, 1M cable
Art:
PR3861A0250BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-5V, 0..400 bar, G1/2 flush, 1M cable
Art:
PR3861A0400BA
Copied
|
|
|
1M Cable outlet screened
|
0-5V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-5V, 0..10 bar, G1/2 flush, M12
Art:
PR3861B0010BA
Copied
|
|
|
M12
|
0-5V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-5V, 0..25 bar, G1/2 flush, M12
Art:
PR3861B0025BA
Copied
|
|
|
M12
|
0-5V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-5V, 0..60 bar, G1/2 flush, M12
Art:
PR3861B0060BA
Copied
|
|
|
M12
|
0-5V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-5V, 0..100 bar, G1/2 flush, M12
Art:
PR3861B0100BA
Copied
|
|
|
M12
|
0-5V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-5V, 0..250 bar, G1/2 flush, M12
Art:
PR3861B0250BA
Copied
|
|
|
M12
|
0-5V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-5V, 0..400 bar, G1/2 flush, M12
Art:
PR3861B0400BA
Copied
|
|
|
M12
|
0-5V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-5V, 0..10 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0010BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-5V, 0..25 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0025BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-5V, 0..60 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0060BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-5V, 0..100 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0100BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-5V, 0..250 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0250BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-5V, 0..400 bar, G1/2 flush, 1M cable IP67
Art:
PR3861C0400BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-5V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-10V, 0..10 bar, G1/2 flush, DIN
Art:
PR3862-0010BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-10V, 0..25 bar, G1/2 flush, DIN
Art:
PR3862-0025BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-10V, 0..60 bar, G1/2 flush, DIN
Art:
PR3862-0060BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-10V, 0..100 bar, G1/2 flush, DIN
Art:
PR3862-0100BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-10V, 0..250 bar, G1/2 flush, DIN
Art:
PR3862-0250BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-10V, 0..400 bar, G1/2 flush, DIN
Art:
PR3862-0400BA
Copied
|
|
|
DIN A 43650
|
0-10V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-10V, 0..10 bar, G1/2 flush, 1M cable
Art:
PR3862A0010BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-10V, 0..25 bar, G1/2 flush, 1M cable
Art:
PR3862A0025BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-10V, 0..60 bar, G1/2 flush, 1M cable
Art:
PR3862A0060BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-10V, 0..100 bar, G1/2 flush, 1M cable
Art:
PR3862A0100BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-10V, 0..250 bar, G1/2 flush, 1M cable
Art:
PR3862A0250BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-10V, 0..400 bar, G1/2 flush, 1M cable
Art:
PR3862A0400BA
Copied
|
|
|
1M Cable outlet screened
|
0-10V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-10V, 0..10 bar, G1/2 flush, M12
Art:
PR3862B0010BA
Copied
|
|
|
M12
|
0-10V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-10V, 0..25 bar, G1/2 flush, M12
Art:
PR3862B0025BA
Copied
|
|
|
M12
|
0-10V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-10V, 0..60 bar, G1/2 flush, M12
Art:
PR3862B0060BA
Copied
|
|
|
M12
|
0-10V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-10V, 0..100 bar, G1/2 flush, M12
Art:
PR3862B0100BA
Copied
|
|
|
M12
|
0-10V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-10V, 0..250 bar, G1/2 flush, M12
Art:
PR3862B0250BA
Copied
|
|
|
M12
|
0-10V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-10V, 0..400 bar, G1/2 flush, M12
Art:
PR3862B0400BA
Copied
|
|
|
M12
|
0-10V
|
600 bar
|
400
|
13-30 V DC
|
| ||
|
0-10V, 0..10 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0010BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
15 bar
|
10
|
13-30 V DC
|
| ||
|
0-10V, 0..25 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0025BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
37.5 bar
|
25
|
13-30 V DC
|
| ||
|
0-10V, 0..60 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0060BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
90 bar
|
60
|
13-30 V DC
|
| ||
|
0-10V, 0..100 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0100BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
150 bar
|
100
|
13-30 V DC
|
| ||
|
0-10V, 0..250 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0250BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
375 bar
|
250
|
13-30 V DC
|
| ||
|
0-10V, 0..400 bar, G1/2 flush, 1M cable IP67
Art:
PR3862C0400BA
Copied
|
|
|
1M Cable outlet screened (IP67)
|
0-10V
|
600 bar
|
400
|
13-30 V DC
|
|
Select a variant in the list