| Approvals | UL, CSA, GL, CSA US, KEMA KUR, EAC |
|---|---|
| Color | Brown |
| Connections | 2 |
| Contamination degree | 3 |
| Country of origin | BG |
| Cross connect channels | 2 |
| Cross section single wire from | 0.5 |
| Cross section single wire to | 4 |
| Cross section stranded wire from | 0.5 |
| Cross section stranded wire to | 4 |
| Cross section stranded with ferrule from | 0.5 |
| Cross section stranded with ferrule to | 2.5 |
| Cross-Section | 2.5 |
| CSA test standard | C22.2 No 158 |
| CSAus test standard | UL 1059 |
| EAC test standard | TR ZU 004/2011 |
| Flamklass | UL94-V0 |
| GL test standard | IEC 60947-7-1:2009 |
| Height TS 35/7.5 | 39 |
| KEMA KEUR test standard | EN 60947-7-1:2009 |
| Length | 59 |
| Number of levels | 1 |
| Number of test pick off options | 2 |
| Operating temperature from | -40 |
|---|---|
| Operating temperature to | 120 |
| Overvoltage category | III |
| Pack Size | 100 |
| Plug gauge acc. EN 60 947-1 | A3 |
| Rated Current CSA | 27 |
| Rated current CSAus | 27 |
| Rated Current IEC | 24 |
| Rated Current To UL | 27 |
| Rated impulse voltage | 8 |
| Rated wire cross section from (AWG) | 20 |
| Rated wire cross section to (AWG) | 12 |
| Rated voltage CSAus | 600 |
| Rated Voltage IEC | 800 |
| Rated Voltage To UL | 600 |
| Stripping Length | 10 |
| Tariff code | 85369010 |
| UL test standard | UL 1059 |
| Weight | 7.6 |
| Width | 5.1 |
| Voltage CSA | 600 |
Modular busbar systems that streamline power distribution, improve safety, and speed up panel builds.
Great electrical installations don't fail because of the major components. They fail because of the small ones that didn't get enough attention.
It's easy to focus on the big-ticket items during specification — and let the terminal blocks become an afterthought. But inferior connection components have a habit of making themselves known over time. Loose connections, degraded insulation, premature failure. The kind of faults that are frustrating to trace and expensive to fix.
Tekox engineer their terminal strips, safety blocks, insulated strips, and porcelain blocks to the standards your installations deserve. Available now from Demesne Electrical — get in touch and we'll show you the range.
Conta-Clip PPVK push-in potential distribution terminals simplify control cabinet wiring with tool-free connections, compact DIN rail mounting, and reliable current distribution up to 41A.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
We’re excited to share some great news at Demesne Electrical. Wayne Moody has joined our team, bringing with him years of experience and a clear vision for the future. His focus will be on building on our strong reputation here in Ireland and driving our growth across Europe.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| My favourites | Articles | Approvals | Color | Connections | Country of origin | Cross connect channels | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Cross-Section | cUL test standard | Diode type | Explosion proof | GL test standard | Height TS 35/7.5 | Length | Load Current Max | Nemko test standard | Pack Size | Plug gauge acc. EN 60 947-1 | Rated Current CSA | Rated current CSAus | Rated current cUL | Rated Current IEC | Rated Current To UL | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Rated voltage CSAus | Rated voltage cUL | Rated Voltage IEC | Rated Voltage To UL | Stripping Length | Weight | Width | Voltage CSA | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ZRK 2.5/2A Brown, 2.5mm² Tension spring, feed through
Art:
3500.0
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Brown
|
2
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
59
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
7.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/2A Black, 2.5mm² Tension spring, feed through
Art:
3500.4
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Black
|
2
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
59
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
7.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/2A Grey 2.5mm² Tension spring, feed through
Art:
3500.6
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Grey
|
2
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
59
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
7.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/2A Yellow, 2.5mm² Tension spring, feed through,
Art:
3500.8
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yellow
|
2
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
59
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
7.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/2A Red, 2.5mm² Tension spring, feed through
Art:
3500.9
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Red
|
2
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
59
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
7.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/3A Yellow, 2.5mm² Tension spring, feed through, 1 in, 2 out
Art:
3501.8
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yellow
|
3
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
71.3
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
9.6
|
5.1
|
600
|
|
||
|
ZRK 2.5/3A Red, 2.5mm² Tension spring, feed through, 1 in, 2 out
Art:
3501.9
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Red
|
3
|
BG
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
IEC 60947-7-1:2009
|
39
|
71.3
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
9.6
|
5.1
|
600
|
|
||
|
ZRK 2,5/2x2A BG
Art:
3503.2
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Beige
|
2 x 2
|
CZ
|
0
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
|
39
|
83.6
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
10.6
|
5.1
|
600
|
|
||
|
ZRK 2,5/2x2A BU
Art:
3503.5
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Blue
|
2 x 2
|
CZ
|
0
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
|
|
39
|
83.6
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
10.6
|
5.1
|
600
|
|
||
|
ZRK 4/2A Grey, 4mm² Tension spring, feed through
Art:
3515.6
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Grey
|
2
|
CZ
|
2
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
IEC 60947-7-1:2009
|
42
|
64
|
32
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
10.2
|
6.1
|
600
|
|
||
|
ZRK 4/2A Yellow, 4mm² Tension spring, feed through
Art:
3515.8
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yellow
|
2
|
CZ
|
2
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
IEC 60947-7-1:2009
|
42
|
64
|
32
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
10.2
|
6.1
|
600
|
|
||
|
ZRK 2.5/2A Red, 2.5mm² Tension spring, feed through
Art:
3515.9
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Red
|
2
|
CZ
|
2
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
IEC 60947-7-1:2009
|
42
|
64
|
32
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
10.2
|
6.1
|
600
|
|
||
|
ZRK 4/3A Yellow, 4mm² Tension spring, feed through, 1 in, 2 out
Art:
3516.8
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yellow
|
3
|
CZ
|
2
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
IEC 60947-7-1:2009
|
42
|
78.5
|
32
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
13.6
|
6.1
|
600
|
|
||
|
ZRK 2.5/3A Red, 2.5mm² Tension spring, feed through, 1 in, 2 out
Art:
3516.9
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Red
|
3
|
CZ
|
2
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
IEC 60947-7-1:2009
|
42
|
78.5
|
32
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
13.6
|
6.1
|
600
|
|
||
|
ZRK 4/2x2A BG
Art:
3518.2
Copied
|
UL, CSA, CSA US, KEMA KUR, NEMKO, EAC
|
Beige
|
2 x 2
|
CZ
|
0
|
0.5
|
6
|
0.6
|
6
|
0.5
|
4
|
4
|
|
|
|
|
42
|
93
|
32
|
EN 60947-7-1:2009
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
15.4
|
6.1
|
600
|
|
||
|
ZRK 2,5/2x2A/D2 BG
Art:
3542.2
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Beige
|
2 x 2
|
BG
|
1
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
1N4007 / 1000V / 1A
|
|
|
39
|
83.6
|
24
|
|
100
|
A3
|
27
|
27
|
|
24
|
1
|
20
|
12
|
600
|
|
800
|
600
|
10
|
1.3
|
5.1
|
600
|
|
||
|
ZRK 6/2A Red, 6mm² Tension spring, feed through
Art:
3581.9
Copied
|
UL, CSA, GL, CSA US, cUL, KEMA KUR, EAC
|
Red
|
2
|
CZ
|
1
|
0.5
|
10
|
0.5
|
10
|
0.5
|
6
|
6
|
C22.2 No 158
|
|
|
IEC 60947-7-1:2009
|
47.5
|
65
|
41
|
|
100
|
A5
|
50
|
50
|
50
|
41
|
50
|
22
|
8
|
600
|
600
|
1000
|
600
|
13
|
17.8
|
8.1
|
600
|
|
||
|
ZRK 10/2A Red, 10mm² Tension spring, feed through
Art:
3597.9
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Red
|
2
|
CZ
|
2
|
1.5
|
16
|
1.5
|
10
|
1.5
|
10
|
10
|
|
|
|
|
50.5
|
73.5
|
57
|
|
50
|
B6
|
55
|
55
|
|
57
|
55
|
16
|
6
|
500
|
|
1000
|
500
|
18
|
26
|
10.1
|
500
|
|
||
|
ZRK 16/2A Green, 16mm² Tension spring, feed through
Art:
3636.1
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Green
|
2
|
CZ
|
2
|
1.5
|
25
|
1.5
|
16
|
1.5
|
16
|
16
|
|
|
|
|
51.5
|
81.5
|
76
|
|
50
|
A7
|
65
|
65
|
|
76
|
|
14
|
4
|
1000
|
|
1000
|
|
18
|
36.45
|
12.1
|
1000
|
|
||
|
ZRK 16/2A Red, 16mm² Tension spring, feed through
Art:
3636.9
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Red
|
2
|
CZ
|
2
|
1.5
|
25
|
1.5
|
16
|
1.5
|
16
|
16
|
|
|
|
|
51.5
|
81.5
|
76
|
|
50
|
A7
|
65
|
65
|
|
76
|
|
14
|
4
|
1000
|
|
1000
|
|
18
|
36.45
|
12.1
|
1000
|
|
||
|
ZRK 2,5/4A Beige, Ex certfied feed through
Art:
1706.2
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Beige
|
4
|
DE
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
Yes
|
IEC 60947-7-1:2009
|
39
|
83.6
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
11.4
|
5.1
|
600
|
|
||
|
ZRK 2,5/4A Blue, Ex certfied feed through
Art:
1706.5
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Blue
|
4
|
DE
|
2
|
0.5
|
4
|
0.5
|
4
|
0.5
|
2.5
|
2.5
|
|
|
Yes
|
IEC 60947-7-1:2009
|
39
|
83.6
|
|
|
100
|
A3
|
27
|
27
|
|
24
|
27
|
20
|
12
|
600
|
|
800
|
600
|
10
|
11.4
|
5.1
|
600
|
|
||
|
ZRK 4/2A Beige, Ex certfied feed through
Art:
1716.2
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Beige
|
2
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
64
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
10.2
|
6.1
|
600
|
|
||
|
ZRK 4/2A Blue, Ex certfied feed through
Art:
1716.5
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Blue
|
2
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
64
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
10.2
|
6.1
|
600
|
|
||
|
ZRK 4/3A Beige, Ex certfied feed through
Art:
1717.2
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Beige
|
3
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
78.5
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
13.6
|
6.1
|
600
|
|
||
|
ZRK 4/3A Blue, Ex certfied feed through
Art:
1717.5
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Blue
|
3
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
78.5
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
13.6
|
6.1
|
600
|
|
||
|
ZRK 4/4A Beige, Ex certfied feed through
Art:
1718.2
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Beige
|
4
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
93
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
16.4
|
6.1
|
600
|
|
||
|
ZRK 4/4A Blue, Ex certfied feed through
Art:
1718.5
Copied
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Blue
|
4
|
DE
|
2
|
0.5
|
6
|
0.5
|
6
|
0.5
|
4
|
4
|
|
|
Yes
|
IEC 60947-7-1:2009
|
42
|
93
|
|
|
100
|
A4
|
35
|
35
|
|
32
|
35
|
20
|
10
|
600
|
|
800
|
600
|
12
|
16.4
|
6.1
|
600
|
|
||
|
ZRK 6/2A Beige, Ex certfied feed through
Art:
1719.2
Copied
|
UL, CSA, GL, CSA US, cUL, KEMA KUR, EAC
|
Beige
|
2
|
DE
|
1
|
0.5
|
10
|
0.5
|
10
|
0.5
|
6
|
6
|
C22.2 No 158
|
|
Yes
|
IEC 60947-7-1:2009
|
47.5
|
65
|
|
|
100
|
A5
|
50
|
50
|
50
|
41
|
50
|
22
|
8
|
600
|
600
|
1000
|
600
|
13
|
17.8
|
8.1
|
600
|
|
||
|
ZRK 6/2A Blue, Ex certfied feed through
Art:
1719.5
Copied
|
UL, CSA, GL, CSA US, cUL, KEMA KUR, EAC
|
Blue
|
2
|
DE
|
1
|
0.5
|
10
|
0.5
|
10
|
0.5
|
6
|
6
|
C22.2 No 158
|
|
Yes
|
IEC 60947-7-1:2009
|
47.5
|
65
|
|
|
100
|
A5
|
50
|
50
|
50
|
41
|
50
|
22
|
8
|
600
|
600
|
1000
|
600
|
13
|
17.8
|
8.1
|
600
|
|
||
|
ZRK 10/2A Beige, Ex certfied feed through
Art:
1720.2
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Beige
|
2
|
DE
|
2
|
1.5
|
16
|
1.5
|
10
|
1.5
|
10
|
10
|
|
|
Yes
|
|
50.5
|
73.5
|
|
|
50
|
B6
|
55
|
55
|
|
57
|
55
|
16
|
6
|
500
|
|
1000
|
500
|
18
|
26
|
10.1
|
500
|
|
||
|
ZRK 10/2A Blue, Ex certfied feed through
Art:
1720.5
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Blue
|
2
|
DE
|
2
|
1.5
|
16
|
1.5
|
10
|
1.5
|
10
|
10
|
|
|
Yes
|
|
50.5
|
73.5
|
|
|
50
|
B6
|
55
|
55
|
|
57
|
55
|
16
|
6
|
500
|
|
1000
|
500
|
18
|
26.6
|
10.1
|
500
|
|
||
|
ZRK 16/2A Beige, Ex certfied feed through
Art:
1721.2
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Beige
|
2
|
DE
|
2
|
1.5
|
25
|
1.5
|
16
|
1.5
|
16
|
16
|
|
|
Yes
|
|
51.5
|
81.5
|
|
|
50
|
A7
|
65
|
65
|
|
76
|
|
14
|
4
|
1000
|
|
1000
|
|
18
|
36.45
|
12.1
|
1000
|
|
||
|
ZRK 16/2A Blue, Ex certfied feed through
Art:
1721.5
Copied
|
UL, CSA, CSA US, KEMA KUR, EAC
|
Blue
|
2
|
DE
|
2
|
1.5
|
25
|
1.5
|
16
|
1.5
|
16
|
16
|
|
|
Yes
|
|
51.5
|
81.5
|
|
|
50
|
A7
|
65
|
65
|
|
76
|
|
14
|
4
|
1000
|
|
1000
|
|
18
|
36.45
|
12.1
|
1000
|
|
Select a variant in the list