PAT Tester Hand Held with User Adjustable Pass Limits & Memory

Code: MARHPAT600
539.26

Location Stock
Cork Available to Order
Tallaght Available to Order
Dungannon Available to Order

Martindale MARHPAT600

PAT Tester Hand Held


Product Overview


The Martindale HPAT600 is a battery powered, hand held PAT tester that is ideal for testing all types of portable appliances. It has a fast automatic test sequence or a simple to operate manual mode which is better suited to a less experienced user.


Manual and Automatic Modes

In automatic mode, the HPAT600 will routinely run through a selected test sequence without any further user interaction unless a failure is encountered.

In manual mode, a connection diagram for the selected test type is shown on the display and each step of a test requires user confirmation by a press of the OK button.

The user can select either the standard 500V insulation test or a 250V option which is required for testing appliances with surge protected circuits. The pass levels can also be adjusted which is particularly useful for testing appliances with long power cords or long extension leads.


Stores Data For 200 Appliances

The HPAT600 stores test data for up to 200 appliances which can be easily reviewed on the instrument if you need to check a result on site. It also has a simulated load test to check the load and ensure that the appliance is switched on with a good fuse.


Product Features

Tests both 240V and 110V appliances
Class I, Class II & power lead tests
I.T. safe 200mA DC earth bond test with two pass level
Displays measured values and PASS/FAIL indication
Supplied with both mains and in-car chargers
250V test option for filtered PSUs & sensitive IT equipment
Memory will hold 200 sets of results (not downloadable)
Rechargeable batteries

Product Specs

Earth Bond Test (IT Safe)
  • Test Current: 200mA DC
  • Test Voltage: 4V DC
  • Range: 0 - 19.99Ω
  • Resolution: 0.01Ω
  • Default Pass Value: 0.1Ω
  • User Selectable Pass Value: 0.1Ω to 0.9Ω in 0.1Ω steps

Insulation Resistance

  • Test Voltage: 
    500V: >500V DC at 1mA 
    250V: >250V DC at 1mA
  • Default Pass Value: Class I - 1MΩ, Class II - 2MΩ
  • User Selectable Pass Value: 0.3MΩ to 1MΩ in 0.1Ω steps, or 1MΩ to 10MΩ in 1MΩ steps

IEC & Extension Lead Test

  • Earth Continuity: 200mA DC
  • Insulation Test: 500V DC
  • Wiring Test: Live, Neutral Continuity& Polarity
  • Earth Bond Default Pass Value: 0.1Ω
  • Earth Bond User Selectable Pass Value: 0.1Ω to 0.9Ω in 0.1Ω steps
  • Insulation Resistance Default Pass Value: 1MΩ
  • Insulation Resistance User Selectable Pass Value: 0.3MΩ to 1MΩ in 0.1Ω steps, or 1MΩ to 10MΩ in 1MΩ steps

Fuse Test

  • Test Voltage: 4V DC
  • Test Current: 200mA DC
  • Pass Level: >2mA


Please click the links below to download the application notes in pdf format.

Common PAT testing errors

How to choose the right PAT

Where can I get my instruments calibrated?



ORDER BEFORE 3PM TODAY FOR EXPRESS DELIVERY

Sign Up For Product Launches & Updates

Enter your email address here

Thank you for signing up to our mailing list