TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling.
  • 30–40A adjustable range
  • Class 10 trip curve
  • Phase-loss sensitivity
  • Manual/auto reset modes
  • Direct mount to TeSys D
Contactor Overload 0.36-0.54a LC1K units

Contactor Overload 0.36-0.54a LC1K units

Contactor Overload 0.54-0.8a LC1K units

Contactor Overload 0.54-0.8a LC1K units

Contactor Overload 0.8-1.2a LC1K units

Contactor Overload 0.8-1.2a LC1K units

Contactor Overload 1.2-1.8a LC1K units

Contactor Overload 1.2-1.8a LC1K units

Contactor Overload 1.8-2.6a LC1K units

Contactor Overload 1.8-2.6a LC1K units

Contactor Overload 2.6-3.7a LC1K units

Contactor Overload 2.6-3.7a LC1K units

Contactor Overload 3.7-5.5a LC1K units

Contactor Overload 3.7-5.5a LC1K units

Contactor Overload 5.5-8.0a LC1K units

Contactor Overload 5.5-8.0a LC1K units

Contactor Overload 0.16-0.25amp LC1D09-38

Contactor Overload 0.16-0.25amp LC1D09-38

Contactor Overload 0.25-0.40amp LC1D09-38

Contactor Overload 0.25-0.40amp LC1D09-38

Contactor Ovreload 0.40-0.63amp LC1D09-38

Contactor Ovreload 0.40-0.63amp LC1D09-38

Contactor Overload 0.63-1.0amp LC1D09-38

Contactor Overload 0.63-1.0amp LC1D09-38

Contactor Overload 1.0-1.6amp  LC1D09-38

Contactor Overload 1.0-1.6amp LC1D09-38

Contactor Overload 1.6-2.5amp  LC1D09-38

Contactor Overload 1.6-2.5amp LC1D09-38

Contactor Overload 2.5-4.0amp  LC1D09-38

Contactor Overload 2.5-4.0amp LC1D09-38

Contactor Overload 4.0-6.0amp  LC1D09-38

Contactor Overload 4.0-6.0amp LC1D09-38

Contactor Overload 5.5-8.0amp  LC1D09-38

Contactor Overload 5.5-8.0amp LC1D09-38

Contactor Overload 7.0-10amp  LC1D09-38

Contactor Overload 7.0-10amp LC1D09-38

Contactor Overload 9.0-13amp  LC1D09-38

Contactor Overload 9.0-13amp LC1D09-38

Contactor Overload 12-18amp  LC1D09-38

Contactor Overload 12-18amp LC1D09-38

Contactor Overload 16-24amp  LC1D09-38

Contactor Overload 16-24amp LC1D09-38

Contactor Overload 23-32amp  LC1D09-38

Contactor Overload 23-32amp LC1D09-38

Contactor Overload 23-32amp LC1D40-65

Contactor Overload 23-32amp LC1D40-65

Contactor Overload 23-32a LC1D40-95

Contactor Overload 23-32a LC1D40-95

Overload relay 37-50A Cls10 ELK

Overload relay 37-50A Cls10 ELK

OVERLOAD RELAY 63 to 80A

OVERLOAD RELAY 63 to 80A

Contactor Overload 30-40amp LC1D40-65

Contactor Overload 30-40amp LC1D40-65

Contactor Overload 80-104amp LC1D80-95

Contactor Overload 80-104amp LC1D80-95

Contactor Overload 30-38amp  LC1D09-38

Contactor Overload 30-38amp LC1D09-38

Contactor Overload 48-65amp LC1D40-65

Contactor Overload 48-65amp LC1D40-65

Selected variant

Avaible in several variants

Selected variant

Specifications

Product description

Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

The TeSys Deca LRD thermal overload relay from Schneider Electric offers reliable motor protection for 30–40A circuits. Designed to guard against overloads, phase loss, and unbalanced currents, it's a compact and easy-to-install solution that pairs directly with TeSys D contactors.

Accessories

DF electrci 485121
Blog

Reliable Protection, Compact Form – Fuse Holders Built to Perform

The DF Electric 485121 fuse holder delivers reliable protection in a compact, DIN-rail-ready design. Built for panel builders who won’t compromise on safety or performance, it’s the trusted choice for tough environments and tight spaces.

stego loop
Blog

Stego Enclosure Heaters with Loop

STEGO’s new loop enclosure heaters are a smart fix for condensation in control cabinets. They heat evenly, install fast with no tools, and come in a range of sizes from 10 to 150 W. They're tough, touch-safe, and even have a built-in thermostat option—everything you need to protect your gear and keep things running smoothly.

draw wire
Blog

Precision in Motion: Kübler Linear Measurement Systems at Demesne Electrical

Precise, Durable Linear Measurement from Kübler
Browse our range of Kübler draw wire encoders and linear measurement systems, designed for accurate position and speed sensing in industrial and OEM applications. Built for tough environments. Trusted by automation professionals.

hora
Blog

New on the Market: RKA Aluminium Terminal Blocks for Copper and Aluminium Conductors

Designed by HORA eTec, the RKA series offers a complete lineup of aluminium terminal blocks built for both aluminium and copper conductors. Every model in the range includes push-through protection, is finger-safe, and is built with installation efficiency in mind. From compact control panels to large-scale systems, here’s the full breakdown—from the RKA 16 to the RKA 300.

telehaase
Blog

Smarter Control Starts Here Explore the TELE Haase Range at Demesne

In complex, high-stakes electrical environments, precision, safety, and performance aren't optional, they're essential. That’s why at Demesne Electrical, we supply solutions that go beyond compliance, empowering engineers and panel builders to build smarter, more connected systems.
One of our most trusted partners in this space is TELE Haase, an industry leader in intelligent monitoring and automation components. From load protection to digital performance sensors, the TELE range offers future-focused tools that streamline system diagnostics and improve long-term reliability.

puls
Blog

Power Supply Efficiency Testing – What Irish Electrical Engineers Need to Know

Think your power supply is running at 95% efficiency?
Don’t just trust the datasheet, test it. In this post, we break down how to accurately measure power supply efficiency using the right tools, setups, and real-world conditions. Essential reading for anyone working with industrial power in Ireland.

My favourites Articles Price

Selected variant

Select a variant in the list

Customer support
Our customer support team answers all kinds of questions.
+35314047700
Send e-mail
Do you need help?

Cookie settings for Demesne

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.

Please login or continue as a guest

To get the best deals
Login | Create account