CONTA-CLIP
The DLI, DLIS range of installation terminals enable the ability to distribute power in a small footprint and gives the ability to disconnect the neutral connections.
To comply to VDE 100 (IEC 364) and VDE 0108, which stipulates the requirement that a circuit's association must be clearly detectable.
It is also required that an insulation test can be performed on each terminal without disconnecting the Neutral wire from the terminal blocks.
This is a specific requirement for public buildings such as hospitals, schools, airports, office buildings and institutions.
The terminals support the use of 10 x 3 busbar and is positioned on the outside of the terminals, the bar is held in place using the HP support plates. A sliding contact that contacts both sides of the busbar is used to connect and disconnect from the busbar.
This sliding contact permits functional testing independent of the operational mode.
| Color | Beige |
|---|---|
| Connections | 4 |
| Contamination degree | 3 |
| Country of origin | CZ |
| Cross connect channels | 2 |
| Cross section single wire from | 0.2 |
| Cross section single wire to | 4 |
| Cross section stranded wire from | 0.2 |
| Cross section stranded wire to | 4 |
| Cross section stranded with ferrule from | 0.2 |
| Cross section stranded with ferrule to | 2.5 |
| Cross-Section | 2.5 |
| Flamklass | UL94-V2 |
| Height TS 35/7.5 | 53 |
| Length | 90.5 |
| Operating temperature from | -40 |
| Operating temperature to | 105 |
| Overvoltage category | III |
|---|---|
| Pack Size | 50 |
| Plug gauge acc. EN 60 947-1 | A3 |
| Rated Current IEC | 24 |
| Rated impulse voltage | 4 |
| Rated wire cross section from (AWG) | 22 |
| Rated wire cross section to (AWG) | 14 |
| Rated Voltage IEC | 400 |
| Screw size | M 2,5 |
| Stripping Length | 8 |
| Tariff code | 85369010 |
| Torque max | 0.8 |
| Torque Min | 0.4 |
| Weight | 26.8 |
| Width | 6 |
The DLI, DLIS range of installation terminals enable the ability to distribute power in a small footprint and gives the ability to disconnect the neutral connections.
To comply to VDE 100 (IEC 364) and VDE 0108, which stipulates the requirement that a circuit's association must be clearly detectable.
It is also required that an insulation test can be performed on each terminal without disconnecting the Neutral wire from the terminal blocks.
This is a specific requirement for public buildings such as hospitals, schools, airports, office buildings and institutions.
The terminals support the use of 10 x 3 busbar and is positioned on the outside of the terminals, the bar is held in place using the HP support plates. A sliding contact that contacts both sides of the busbar is used to connect and disconnect from the busbar.
This sliding contact permits functional testing independent of the operational mode.
Modular busbar systems that streamline power distribution, improve safety, and speed up panel builds.
Great electrical installations don't fail because of the major components. They fail because of the small ones that didn't get enough attention.
It's easy to focus on the big-ticket items during specification — and let the terminal blocks become an afterthought. But inferior connection components have a habit of making themselves known over time. Loose connections, degraded insulation, premature failure. The kind of faults that are frustrating to trace and expensive to fix.
Tekox engineer their terminal strips, safety blocks, insulated strips, and porcelain blocks to the standards your installations deserve. Available now from Demesne Electrical — get in touch and we'll show you the range.
Conta-Clip PPVK push-in potential distribution terminals simplify control cabinet wiring with tool-free connections, compact DIN rail mounting, and reliable current distribution up to 41A.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
We’re excited to share some great news at Demesne Electrical. Wayne Moody has joined our team, bringing with him years of experience and a clear vision for the future. His focus will be on building on our strong reputation here in Ireland and driving our growth across Europe.
The PMX fuse holder range is compact, halogen-free, and manufactured in Europe for fast availability. Available in 10×38, 14×51, and 22×58 sizes with IEC, UL, and CSA approvals, they feature silver-plated contacts, IP20 touch-safe design, and optional blown fuse indicators — giving panel builders reliable, safe, and flexible protection.
|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| My favourites | Articles | Additional information | Approvals | Color | Connections | Contamination degree | Country of origin | Cross connect channels | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Cross-Section | CSA test standard | CSAus test standard | EAC test standard | Flamklass | Height TS 35/7.5 | KEMA KEUR test standard | Length | Operating temperature from | Operating temperature to | Overvoltage category | Pack Size | Plug gauge acc. EN 60 947-1 | Rated Current IEC | Rated impulse voltage | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Rated Voltage IEC | Screw size | Stripping Length | Tariff code | Torque max | Torque Min | Weight | Width | Price | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DLIS 2.5 PE/L/NT, 2.5mm² installation terminal, PE, live, neutral, busbar
Art:
1410.2
Copied
|
|
|
Beige
|
4
|
3
|
CZ
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
26.8
|
6
|
|
||
|
DLIS 2.5 PE/L/N, 2.5mm² installation terminal, PE, live, neutral
Art:
1411.2
Copied
|
|
|
Beige
|
5
|
3
|
CZ
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
24.08
|
6
|
|
||
|
DLIS 2.5 PE/L/L, 2.5mm² installation terminal, PE, live, live
Art:
1412.2
Copied
|
|
|
Beige
|
5
|
3
|
CZ
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
24.08
|
6
|
|
||
|
DLIS 2.5 L/N, 2.5mm² installation terminal, live, neutral
Art:
1413.2
Copied
|
|
|
Beige
|
4
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
14.04
|
6
|
|
||
|
DLIS 2.5 L/L, 2.5mm² installation terminal, live, live
Art:
1414.2
Copied
|
|
|
Beige
|
4
|
3
|
CZ
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
14.04
|
6
|
|
||
|
DLIS 2.5 N, 2.5mm² installation terminal, neutral
Art:
1415.2
Copied
|
|
|
Beige
|
2
|
3
|
DE
|
1
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
10.76
|
6
|
|
||
|
DLIS 2.5 L, 2.5mm² installation terminal, live
Art:
1416.2
Copied
|
|
|
Beige
|
2
|
3
|
DE
|
1
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
10.76
|
6
|
|
||
|
DLI 2,5 PE/L/NT, 2.5mm² installation terminal, PE, live, neutral, slide
Art:
1417.2
Copied
|
|
EAC
|
Beige
|
5
|
3
|
DE
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
TR ZU 004/2011
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
28.76
|
6
|
|
||
|
DLI 2,5 PE/L/N, 2.5mm² installation terminal, PE, live, neutral,
Art:
1418.2
Copied
|
|
CSA, CSA US, KEMA KUR, EAC
|
Beige
|
5
|
3
|
DE
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
26.08
|
6
|
|
||
|
DLI 2.5 PE/L/L, 2.5mm² installation terminal, PE, live, live
Art:
1419.2
Copied
|
|
CSA, CSA US, KEMA KUR, EAC
|
Beige
|
5
|
3
|
CZ
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
26.08
|
6
|
|
||
|
DLI 2,5 L/N, 2.5mm² installation terminal, live, neutral
Art:
1420.2
Copied
|
|
CSA, CSA US, KEMA KUR, EAC
|
Beige
|
4
|
3
|
DE
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
EN 60947-7-1:2009
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
16.08
|
6
|
|
||
|
DLI 2,5 L/L, 2.5mm² installation terminal, live, live
Art:
1421.2
Copied
|
|
CSA, CSA US, KEMA KUR, EAC
|
Beige
|
4
|
3
|
DE
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
EN 60947-7-1:2009
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
16.08
|
6
|
|
||
|
DLI 2,5 N, 2.5mm² installation terminal, neutral
Art:
1422.2
Copied
|
|
CSA, CSA US, EAC
|
Beige
|
2
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
12.12
|
6
|
|
||
|
DLI 2,5 L, 2.5mm² installation terminal, live
Art:
1423.2
Copied
|
|
CSA, CSA US, EAC
|
Beige
|
2
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
50
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
12.12
|
6
|
|
||
|
DLIS 2.5 B-W, 2.5mm² installation 3-phase terminal block
Art:
1446.2
Copied
|
block for AC application
|
|
Beige
|
12
|
3
|
DE
|
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
16
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
80.43
|
18
|
|
||
|
DLIS 2.5 B-D, 2.5mm² installation 3-phase terminal block
Art:
1447.2
Copied
|
block for 3-phase application
|
|
Beige
|
8
|
3
|
DE
|
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
25
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
41.44
|
12
|
|
||
|
DLI 2,5 B-W, 2.5mm² installation terminal block, slide
Art:
1448.2
Copied
|
block for AC application
|
EAC
|
Beige
|
15
|
3
|
DE
|
3
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
TR ZU 004/2011
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
16
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
86.25
|
18
|
|
||
|
DLI 2,5 B-D, 2.5mm² installation 3-phase terminal block, slide
Art:
1449.2
Copied
|
block for 3-phase application
|
EAC
|
Beige
|
9
|
3
|
DE
|
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
TR ZU 004/2011
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
25
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
44.63
|
12
|
|
||
|
DLI 2,5 D, 2.5mm² installation terminal, live
Art:
1490.2
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
DLIS 2.5 B-3L/3N/3PE, 2.5mm² installation terminal block, 3 x PE, 3 x live, 3 x neutral
Art:
2715.2
Copied
|
block for AC application
|
|
Beige
|
15
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
16
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
69.27
|
18
|
|
||
|
DLIS 2.5 B-3L/N/PE, 2.5mm² installation terminal block, PE, 3 x live, neutral
Art:
2716.2
Copied
|
block for 3-phase application
|
|
Beige
|
9
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
25
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
48.04
|
18
|
|
||
|
DLIS 2.5 B-6L, 2.5mm² installation terminal block, 6 x live
Art:
2717.2
Copied
|
|
|
Beige
|
12
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
16
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
42.23
|
18
|
|
||
|
DLIS 2.5 B-6L/3PE, 2.5mm² installation terminal block, 3 x PE, 3 x live
Art:
2718.2
Copied
|
|
|
Beige
|
15
|
3
|
DE
|
2
|
0.2
|
4
|
0.2
|
4
|
0.2
|
2.5
|
2.5
|
|
|
|
UL94-V2
|
53
|
|
90.5
|
-40
|
105
|
III
|
16
|
A3
|
24
|
4
|
22
|
14
|
400
|
M 2,5
|
8
|
85369010
|
0.8
|
0.4
|
72.23
|
18
|
|
Select a variant in the list